Reliable MSK-8900M Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Nähmaschinen Reliable MSK-8900M herunter. Reliable MSK-8900M Installation manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 108
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - LTC 8900 Series

LTC 8900 Series en Installation Manual

Seite 2

17. Attachments, changes or modifications - Only use attachments/accessories specified bythe manufacturer. Any change or modification of the equipment

Seite 3 - Table of contents

CPU and Data Receiver LED Indicators:PCB ID PCB Label Color FunctionD1000 RESET Red Lit during reset conditionD0908 CPU ACT. Green Flashes to indicate

Seite 4

Maintenance InformationNOTE: The LTC 8900 Allegiant system has been designed to perform for long periods of timewith little or no maintenance. Cleanin

Seite 5

Figure 10.2: Line Voltage Selector RemovalMatrix Bay AC Line Fuse ReplacementThe AC line fuse on LTC 8805/60 and LTC 8906/60 Power Supply models is lo

Seite 6 - Safety Precautions

Remove the fuse from the holder (as in , page 102), and replace it with a fuse of the samerating (1.6 A, 250 V) for continued protection. Reinstall th

Seite 7 - Safety precautions

6. Wait for the System Supervisor to indicate that the Data Mirroring process hascompleted. This step takes a few minutes.7. From the System Superviso

Seite 8 - Important safety instructions

The two batteries are mounted on the front edge of the CPU card and are about 25 mm (1 in.)in diameter. Insert a small flat blade screwdriver into the

Seite 9 - Safety

PinoutsB.1 LTC 8900 Series CPU Bay Rear Panel Connector Pinouts B.1.1 Console Port RS-232 PinoutsPin # . . . . . . . . . . . . . . . . . . . .Designa

Seite 11 - Safety

Bosch Security Systems, Inc.850 Greenfield RoadLancaster, PA, 17601USAwww.boschsecurity.com© Bosch Security Systems, Inc., 2015Bosch Sicherheitssyst

Seite 12

– Connect outdoor equipment to the unit's inputs only after this unit has had its groundingplug connected to a grounded outlet or its ground term

Seite 13 - FCC & ICES compliance

The system ground is only used to comply with safety standards or installation practices incertain countries. Bosch does not recommend connecting syst

Seite 14 - Bosch notices

FCC & ICES complianceFCC & ICES Information(U.S.A. and Canadian Models Only)This device complies with part 15 of the FCC Rules. Operation is s

Seite 15 - Unpacking

Notice!This is a class A product. In a domestic environment this product may cause radiointerference, in which case the user may be required to take a

Seite 16 - Introduction

UnpackingThis equipment should be unpacked and handled with care. If an item appears to have beendamaged in shipment, notify the shipper immediately.V

Seite 17 - System Components

IntroductionThis manual covers the installation of the Allegiant® LTC 8900 Series systems. Information onsystem operation and information on the PC so

Seite 18

System ComponentsLTC 8904 Series CPU BayThis unit provides central control for the entire system. It contains all the system'sconfiguration infor

Seite 19

first input bay configuration are looped using video ribbon cables to the next group of inputbays. This sequence continues for each LTC 8902 Series Ou

Seite 20 - Utilizing LTC 8904 Series CPU

LTC 8946/93 LAN SwitchesThe LTC 8946/93 is a 10/100Base-T Ethernet LAN switch that provides a communication linkbetween the LTC 8904 Series main CPU b

Seite 22 - Installation

Hardware Installation Procedure for Standard SystemsUtilizing LTC 8904 Series CPUGeneral Installation Considerations(Refer to Hardware Installation Pr

Seite 23 - IN S R -T O L

LTC 8902Monitor BayLTC 8946 LAN Switch LTC 8904 CPU BayLTC 8902Monitor BayLTC 8903Camera BayLTC 8903Camera BayLTC 8903Camera BayLTC 8903Camera BayLTC

Seite 24

LAN Switch InstallationThe LTC 8946/93 is a standard 10/100 Base-T network switch. Disregard the originalmanufacturers instructions supplied with the

Seite 25

Module InsertionA special tool is supplied with the system components, for insertion of the Data Receiver,Video Input Module, and Video Output Module

Seite 26

Verify that switches located on dipswitch S1 and S3 are all OFF.On dipswitch S2 of the LTC8916/01, verify that switches 1 to 4 are OFF. Switch 8 shoul

Seite 27 - System Video Connections

1 2 3 4 Camera Number RangeON OFF ON ON 2817 to 3072ON ON OFF OFF 3073 to 3328ON ON OFF ON 3329 to 3584ON ON ON OFF 3585 to 3840ON ON ON ON 3841 to 40

Seite 28 - Termination Practices

Figure 5.6: Typical Video Output Module InsertionThe LTC 8934/00 Video Output Modules contain five (5) 8-position dip switches. DIP switchS1001 is res

Seite 29 - System Data Connections

All LTC 8921/00 Video Input Modules are identical and can be swapped anywhere within thebay without making any changes to the module except to maintai

Seite 30 - Main Power Connections

The LTC 8903 Series bay s VIDEO OUT connectors are labeled A through D, and the MonitorBay VIDEO BUS connectors are labeled CAMERA BAY OUTPUT A throug

Seite 31 - General Information

Each LTC 8921/00 VIM card provides outputs for 32 monitors. The LTC 8903 Series bayprovides 64 outputs, two LTC 8921/00 VIM cards for each 32 inputs (

Seite 32 - 8901 Series CPU

Table of contents1Safety 61.1 Safety precautions 71.2 Important safety instructions 81.3 Important notices 101.4 FCC & ICES compliance 131.5 UL ce

Seite 33 - Series CPU

The number of available LAN ports can be increased by cascading multiple LTC 8946/93 LANswitches. Each LTC 8946/93 provides 10 additional ports. Addit

Seite 34

Hardware Installation Procedure for RedundantSystem Configuration Utilizing LTC 8901 Series CPURefer to for Installation Procedure for standard system

Seite 35 - LTC 8903 Camera Bay

MainsPrimaryPower SupplyLTC 8910Primary CPULTC 8917Relay BoardBackupPower SupplyLTC 8910Backup CPUPrimary ControllerPrimary LANKeyboards 1-8AlarmBipha

Seite 36

1 3 5 7 5 1 12 4 6 8 1 0 1 2hPP o w e rF a u ltP ro C u rv e S w itc hJ9 0 1 9BR e s e tC le arL E DM o d eC o n s o le2 5 1 0-2 41 3 1 5 1 7 1 9 2 1

Seite 37 - Main CPU Bay Installation

With this in place, data coming from the in-use CPU will go to all other ports on both switches.This allows the video bays to be connected to any port

Seite 38

Monitors 1-64Cameras 1-256Logical Monitor Numbers 1-64LTC 8902 Monitor BayLTC 8903 Camera BayFigure 6.3: Non Fault-tolerant 256 Camera x 64 Monitor Sy

Seite 39

Monitors 33-64Monitors 1-32Cameras 1-256Monitor Outputs 1-32Logical Monitor Numbers 1-32Monitor Outputs 65-96Logical Monitor Numbers 33-64LTC 8902 Mon

Seite 40 - Module Insertion

5. Install the LTC 8902 Series and LTC 8903 Series matrix bays close enough to the systemLAN switches (LTC 8944/93, LTC 8945/93, and LTC 8946/93) so t

Seite 41

P rima ryBa ck -U pP ow erIn U s eC PU A ctiv ityFa u ltC on trolle r A c tivityAu toP rima ry C P UBa ck -U p C P UP ow erIn U s eC PU A ctiv it

Seite 42

!Caution!Important considerations related to the LTC 8943/95 System Controller PC:This PC contains a solid state hard drive with limited storage capac

Seite 43

5.12.2 Second Level LTC 8903 Series Terminations 295.12.3 LTC 8902 Series Terminators 295.13 System Data Connections 295.13.1 LTC 8904 Series CPU Data

Seite 44

Install the power supply in the far right position of the bay, ensuring proper alignment andseating of the supply into the rear mating connector. Veri

Seite 45

IN S R -T O LFigure 6.8: Example of Insertion Tool UseData Receiver ModulesLTC 8902 Series Video Output bays are supplied with LTC 8916/01 Data Receiv

Seite 46

5 6 7 Monitor RangeON OFF OFF 257 to 320ON OFF ON 321 to 384ON ON OFF 385 to 448ON ON ON 449 to 512Table 6.1: LTC 8916/01 Data Receiver Module Switch

Seite 47

1 2 3 4 Camera Number RangeON ON ON OFF 3585 to 3840ON ON ON ON 3841 to 4096Table 6.2: LTC 8918/01 Data Receiver Module (used in LTC 8903 Series bays)

Seite 48

Figure 6.10: Typical Video Output Module InsertionThe LTC 8934/00 Video Output Modules contain five (5) 8-position dip switches. DIP switchS1001 is re

Seite 49

All LTC 8921/00 Video Input Modules are identical and can be swapped anywhere within thebay without making any changes to the module, except to mainta

Seite 50 - Relay Out

The LTC 8903 Series bay s VIDEO OUT connectors are labeled A through D, and the MonitorBay VIDEO BUS connectors are labeled CAMERA BAY OUTPUT A throug

Seite 51

LTC 8903 Series bay provides 64 outputs, two LTC 8921/00 VIM cards are required for each32 inputs (when more than 32 monitors are being served by the

Seite 52

Note that the LTC 8943/95 System Controller PC is supplied with a third LAN port. This port isavailable for connecting the PC to the user s Ethernet n

Seite 53

NOTE: Before attaching the AC line cord to the LTC 8943/95 System Controller PC, verify thatthe line voltage selector switch next to the AC plug is se

Seite 54

6.17 LTC 8901 Series CPU Selection Switch 517Camera Phasing and Accessory Installation 527.1 Camera Phasing Information 527.2 External Sync Informatio

Seite 55

3. After the PC enters the Windows desktop screen, the Allegiant server program shouldstart automatically. If the automatic feature has been disabled,

Seite 56

ConnectorPositionsFunctions Description7 & 8 Relay - Backup CPU Fault Normal open, closes when Backup CPUfailure is detected9 & 10 Relay - Any

Seite 57

Camera Phasing and Accessory InstallationCamera Phasing InformationNOTE: All cameras should be vertically phased properly with each other. The LTC 890

Seite 58

Signal Distribution Unit HookupThe LTC 8900 Series CPU bay provides a single Biphase control code output which can beconnected to a LTC 8568 or LTC 87

Seite 59

The LTC 8900 Series CPU does not provide a direct printer port. The CONSOLE interface portof the CPU can be configured to operate as a Printer output

Seite 60

Satellite System Configuration InstallationsA satellite system configuration is usually used for a medium to large distributed system, or toobtain ext

Seite 61

Allegiant Satellite System Configuration InstallationsAny Allegiant Series switcher model (LTC 8300, LTC 8500, LTC 8600, LTC 8800, or LTC 8900)can be

Seite 62

An Allegiant Biphase control data line from the code distribution unit at the Main site must beprovided to each satellite site. This data line carries

Seite 63

Model No. Maximum Number of System Cameras1LTC 8900 Series 61441. Camera inputs at all sites, plus trunk lines.The Main site system must be programmed

Seite 64

Figure 8.3: Conceptual Diagram of an Allegiant Satellite Switching SystemLTC 8900 SeriesSatellite System Configuration Installations | en 59Bosch Secu

Seite 65 - Configurations

SafetySécuritéAttention : l'installation doit exclusivement être réalisée par dupersonnel qualifié, conformément au code nationald'électrici

Seite 66

Figure 8.4: Conceptual Diagram of a Dual Master Allegiant Satellite System60en | Satellite System Configuration Installations LTC 8900 Series2015.01 |

Seite 67

Typical BiphaseData lines to all localP/T/Z camerasTypical Allegiant ‘Primary’ Master Site 11 or More VideoTRUNK LinesBiphase Data Line toIntermediate

Seite 68

Satellite Site “Trunk Line” Monitor OutputsAt each of the remote satellite sites, a desired number of monitor outputs from the switchermust be assigne

Seite 69

Figure 8.6: Satellite Site Sample Program Showing Logical Camera Numbers and TitlesTo maintain a sense of order, it is preferable to program a satelli

Seite 70 - F01U289924

camera number lines in the table may be reserved at this time for future expansion. If a localtitle is specified, the camera’s title can also be enter

Seite 71

Figure 8.8: Main Site Sample Program Showing Monitor Start-Up Camera NumbersSpecial Programming for “Cascaded” Satellite SystemConfigurationsIn a 3-ti

Seite 72

In default cascaded satellite system configurations, satellite switching commands are notassociated with a user priority level. When a switching comma

Seite 73

Keyboard1 234 5678COM1COM2Console AlarmBiphaseSwitch ControlBack Up ControllerPrimary Controller Relay OutLANPrimary Back UpFigure 8.10: Rear Panel Vi

Seite 74 - LAN Data Line

LTC 8902Monitors 1-64S1 - all offS2 - 8 onLTC 8902Monitors 65-128S1 - all offS2 - 7,8 onLTC 8902Monitors 129-192S1 - all offS2 - 6,8 onLTC 8902Monitor

Seite 75 - 9 10 11 12

Figure 8.13: Rear Panel View of LTC 8902 Series and LTC 8903 Series Video Matrix BaysLTC 8900 Series Satellite System Configuration Installations | en

Seite 76

VeiligheidsmaatregelenAttentie: het apparaat mag alleen door gekwalificeerdpersoneel worden geïnstalleerd. De installatie dient inovereenstemming met

Seite 77 - "D "

F01U289924Figure 8.14: Cable and Accessory Diagrams 70 en | Satellite System Configuration Installations LTC 8900 Series2015.01 | 10.6 | Installation

Seite 78 - LTC 8808 Video Panels

Main ACLineLegacy Parallel Port Switch ControlInterfaceComm Port 2(Spare)4x USB portsPrimary LAN Port (Connect to Primary IP BackUp LAN Port (Connect

Seite 79

Up to 256 System Cameras can be Connected using 8 LTC 8808 Panels(Continue LTC 8808 Sequence as Necessary)Additional LTC 8808Video Interconnect Panels

Seite 80

1323364Typical Connectionsfor up to 64 System MonitorsLTC 8808 VideoInterconnect PanelLTC 8808 VideoInterconnect PanelLowerLTC 8809Ribbon Cable(Monito

Seite 81 - Up to 512 System Monitors

1 3 5 7 5 1 12 4 6 8 1 0 1 2hPP o w e rF a u ltP ro C u rv e S w itc hJ9 0 1 9BR e s e tC le arL E DM o d eC o n s o le2 5 1 0-2 41 3 1 5 1 7 1 9 2 1

Seite 82 - 1 4 5 8 9 12 13 16

1 3 5 7 5 1 12 4 6 8 1 0 1 2hPP o w e rF a u ltP ro C u rv e S w itc hJ9 0 1 9BR e s e tC le arL E DM o d eC o n s o le2 5 1 0-2 41 3 1 5 1 7 1 9 2 1

Seite 83 - LTC 8902

1 3 5 7 5 1 12 4 6 8 1 0 1 2hPP o w e rF a u ltP ro C u rv e S w itc hJ9 0 1 9BR e s e tC le arL E DM o d eC o n s o le2 5 1 0-2 41 3 1 5 1 7 1 9 2 1

Seite 84 - LT C 8903

"A "1234123412341234"B ""C ""D "Each Line Representsan LTC 8809 Ribbon CableLTC 8902 MonitorBay Containing Mod

Seite 85

LTC 8910CPU ModuleLTC 8905PowerSupplyUp To 256CamerasLTC 8903 Video Input BayLTC 8902 Video Output BayLTC 8904 Main CPU BayLAN Data LinesLTC 8809 Co

Seite 86

Up To 256CamerasLTC 8903 VideoInput BayLTC 8902 Video Output BayLTC 8901 Main CPU BayLTC 8808Video PanelsLTC 8903 Video Input BayLTC 8902 VideoOutput

Seite 87

!Warning!Medium risk: Indicates a potentially hazardous situation.If not avoided, this could result in minor or moderate bodily injury.!Caution!Low ri

Seite 88 - "D"

To Monitors 1–64LTC 8944 SwitchLTC 8945 SwitchLTC 8946 SwitchLTC 8943 PCRunningConfigurationSoftwareLTC 8901Main CPU BayLAN Data Lines to All BaysTo M

Seite 89

AdditionalCamerasLTC 8808 Video PanelsLTC 8809 CoaxRibbon Cables LTC 8901Main CPU BayLAN Data Lines to All BaysUp to 64 System Keyboards (Using L

Seite 90 - "A 1"

1 4 5 8 9 12 13 16 1to1617to3233to4849to6465to8081to9697 to112113 to128129 to144145 to160161 to176177 to192193 to208209 to224225 to240241 to256<--&

Seite 91

"A "1234123412341234"B ""C ""D ""A "1234123412341234"B ""C ""D "4 LTC

Seite 92

"A "1234123412341234"B""C ""D ""A "1234123412341234"B""C ""D "LT C 89

Seite 93

"A "1234123412341234"B ""C ""D "oLower LTC 8809Ribbon CableUpper LTC 8809Ribbon CableTo “A1”To “D1”“B2”“B1”“C1

Seite 94 - Connections

"A "1234123412341234"B ""C ""D "16 LTC 8921 Video Input Modules are Required for Camera Inputs 1 to 256LTC 890

Seite 95 - Connections

"A "1234123412341234"B ""C ""D "16 LTC 8921 Video Input Modules are Required for Camera Inputs 1 to 2568 LTC 8

Seite 96

"A"1234123412341234"B""C ""D"16 LTC 8921 Video Input Modules are Required for Camera Inputs 1 to 25616 LTC 892

Seite 97

16 LTC 8921 Video Input Modules are Required for Camera Inputs 1025 to 128016 LTC 8921 Video Input Modules are Required for Camera Inputs 1281 to 1536

Seite 98 - Troubleshooting Guide

8. Overloading - Do not overload outlets and extension cords. This can cause fire orelectrical shock.9. Power supply cord and plug protection - Protec

Seite 99 - Table 9.2: Trouble Modes

"A "1234123412341234"B ""C ""D """D 1""C 1""B 1""A 1"Each Line Re

Seite 100 - Table 9.3: LED Indicators

"A "1234123412341234"B ""C ""D ""A "1234123412341234"B ""C ""D "Lower

Seite 101 - Maintenance Information

"A "1234123412341234"B ""C ""D ""A "1234123412341234"B ""C ""D "Front

Seite 102 - Figure 10.3: Fuse Removal

"A "1234123412341234"B""C ""D ""A "1234123412341234"B""C ""D "LTC 8902

Seite 103

System Cameras Connect to First Level LTC 8903 Video Input Bay16 LTC 8921 Video Input Modules are Required for Cameras 1 to 256System Cameras Connect

Seite 104

System Cameras Connect to First Level LTC 8903 Video Input Bay16 LTC 8921 Video Input Modules are Required for Cameras 1 to 256System Cameras Connect

Seite 105

Set all LTC 8921 ModuleTermination Switches Inside“Primary” First Level LTC 8903 Bays to OFFSystem Cameras Connect to “Primary” First Level LTC 8903 B

Seite 106

Figure 8.42: Front View, Module Placement and Termination Settings, 2048 Camera by 96 Monitor SystemSet all LTC 8921 ModuleTermination Switches Inside

Seite 107

Troubleshooting GuideThe LTC 8900 Allegiant system was designed to provide very high reliability. However, if afailure does occur, the effects of the

Seite 108

Limited keyboard functions If possible, perform a local keyboard test to verify operation ofall keys. If a local test cannot be performed, replace the

Kommentare zu diesen Handbüchern